Ohio home inspector finds water heater not fully functioning: The thermal image shows an electric water heater with temperature readings indicating that the top heating element appears to be working, while the lower element might not be. Let’s break this down to understand why this suggests the lower heating element may need to be replaced.
Electric water heaters typically have two heating elements: one near the top and one near the bottom of the tank. These elements work together to heat the water, but they operate independently based on the thermostat settings and the demand for hot water. The upper element usually heats the water at the top of the tank first, and once the upper thermostat is satisfied (i.e., the water at the top reaches the set temperature), the lower element kicks in to heat the water in the bottom of the tank.
In your thermal image: These temps are being shown through the insulated tank, so the temps are not what exactly what the water temperatures are.
- The temperature at the top of the water heater is relatively warm.
- The temperature in the middle of the tank, where the lower element would typically be located, is significantly cooler.
- The temperature at the bottom of the tank is quite cold.
This temperature gradient suggests that the upper heating element is functioning, as the top of the tank is warmer. However, the lower part of the tank is much cooler, which indicates that the lower heating element may not be working properly. Here’s why:
- Upper Element Working: The warmer temperature at the top aligns with the upper element heating the water in that region. In a typical electric water heater, the upper thermostat prioritizes heating the top of the tank, and once that water is hot enough, it stops the upper element and activates the lower element.
- Lower Element Not Heating: The significant drop in temperature toward the middle and bottom of the tank suggests that the lower element isn’t contributing to heating the water. If the lower element were working, you’d expect the temperature in the lower part of the tank to be closer to the temperature at the top, or at least warmer, since hot water rises and cold water sinks.
- Thermal Stratification: Water heaters naturally exhibit thermal stratification, where the hot water stays at the top and the colder water settles at the bottom. However, the temperature difference here is quite large, and the cold bottom temperature indicates that little to no heating is happening in the lower part of the tank.
Why the Lower Element May Need Replacement
The lower element might not be working due to several possible issues:
- Burned-Out Element: Heating elements can fail over time due to wear, sediment buildup, or electrical issues. If the lower element is burned out, it won’t heat the water, leading to the temperature profile you’re seeing in the thermal image.
- Thermostat Issue: Each element has its own thermostat. If the lower thermostat is malfunctioning, it might not be signaling the lower element to turn on, even if the element itself is fine.
- Wiring or Power Supply Problem: There could be an issue with the electrical connection to the lower element, such as a loose wire, a tripped breaker, or a blown fuse, preventing it from receiving power.
- Sediment Buildup: Over time, sediment can accumulate at the bottom of the tank, covering the lower element. This can cause the element to overheat and fail, as it struggles to transfer heat to the water through the sediment layer.
Why It’s Likely Just the Lower Element
Since the upper element appears to be working (as evidenced by the warmer temperature at the top), the issue is localized to the lower part of the system. If both elements were failing, you’d expect the entire tank to be closer to the ambient temperature. The fact that the top is warm strongly suggests the upper element and its thermostat are functioning, narrowing the problem to the lower element or its associated components.
Next Steps
To confirm that the lower element needs replacement, you can:
- Test the Element: Use a multimeter to check the resistance of the lower heating element. A functioning element typically has a resistance of 10–16 ohms (depending on its wattage). If the resistance is infinite, the element is burned out and needs replacement.
- Check the Thermostat: Test the lower thermostat to ensure it’s working correctly. If the thermostat is faulty, it might not be activating the element.
- Inspect Wiring: Ensure there are no electrical issues preventing power from reaching the lower element.
- Drain and Inspect: If sediment buildup is suspected, drain the tank and inspect the lower element. If it’s covered in sediment, you may need to clean the tank and replace the element.
In summary, the thermal image indicates that the lower heating element is likely not functioning, as the lower part of the tank is significantly colder than the top. Replacing the lower element, after confirming with a multimeter test, is a good starting point to resolve the issue. Typically thermal imaging is not use on water heaters during a home inspection. This water heater rapidly ran out of supplying hot water so further investigation was done. For more information on Thermal Imaging visit this page.